Source current: 35 mA max.
Residual voltage: 0.4 V max.(at source current of 35 mA)
It is easy to adjust the position of phase Z with the origin indication function. The following illustration shows the relationship between phase Z and its origin. Set cut face D to the phase Z origin as shown in the illustration.
• Do not extend the length of the cable to more than 2 m. If the cable must be more than 2 m, use a Model with a Line-driver Output (max. length: 100 m).
● Wiring
Spurious pulses may be generated when power is turned ON and OFF. Wait at least 0.1 s after turning ON the power to the Encoder before using the connected device, and stop using the connected device at least 0.1 s before turning OFF the power to the Encoder. Also, turn ON the power to the load only after turning ON the power to the Encoder.